YASKAWA - RC5
Power Regenerative Unit
Instruction Manual
MANUAL NO. TOEP C710656 01C
Models:
200 V Class, Three-Phase Input: 3.7 to 37 kW
400 V Class, Three-Phase Input: 3.7 to 75 kW
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
Type:
CIMR-R5U
Przeglądanie stron 0
1 2 3 4 5 6 ... 68 69

Podsumowanie treści

Strona 1 - YASKAWA - RC5

YASKAWA - RC5Power Regenerative UnitInstruction ManualMANUAL NO. TOEP C710656 01CModels: 200 V Class, Three-Phase Input: 3.7 to 37 kW400 V Class, Th

Strona 2 - This Page Intentionally Blank

i.3 Notes for Safe Operation8 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual◆ Warning LabelA warning label is displayed on the

Strona 3 - Table of Contents

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 111ReceivingThis chapter describes how to verify the RC5 after delivery to the use

Strona 4

12 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual1.1 Section Safety1.1 Section SafetyCAUTION Do not install or operate any power

Strona 5

1.2 Inspection CheckpointsYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 131.2 Inspection Checkpoints◆ Receiving Checkpoints Ta

Strona 6 - ASME A17.5

1.2 Inspection Checkpoints14 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualThis page intentionally blank.

Strona 7

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 152InstallationThis chapter describes the configuration, location and space when m

Strona 8

16 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual2.1 Section Safety2.1 Section SafetyCAUTION Lift the cabinet by the base. When

Strona 9

2.2 Checking Installation SiteYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 172.2 Checking Installation Site◆ Installation Sit

Strona 10 - ◆ Warning Label

18 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual2.3 Clearances2.3 ClearancesInstall the RC5 vertically and allow sufficient cle

Strona 11 - Receiving

2.4 DimensionsYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 192.4 Dimensions ◆ Models of 200 V/400 V 30 kW and LowerFigure 2.2

Strona 12 - CAUTION

2 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualThis Page Intentionally BlankCopyright 2008 YASKAWA ELECTRIC CORPORATION. All

Strona 13 - 1.2 Inspection Checkpoints

2.4 Dimensions20 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualTable 2.1 RC5 Dimensions mm (in) and Approx. Mass (kg)Note: RC5

Strona 14 - 1.2 Inspection Checkpoints

2.5 Removing and Replacing the Front CoverYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 212.5 Removing and Replacing the Front

Strona 15 - Installation

22 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual2.6 Removing and Replacing the LCD Monitor/Digital Operator2.6 Removing and Rep

Strona 16

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 233Wiring3.1 SECTION SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 17 - ◆ Installation Site

24 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual3.1 Section Safety3.1 Section SafetyW ARNING Only commence wiring after verifyi

Strona 18 - 2.3 Clearances

3.2 Connection DiagramYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 253.2 Connection Diagram◆ Connection Diagram with DriveFig

Strona 19 - 2.4 Dimensions

26 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual3.3 Selecting Peripheral Devices3.3 Selecting Peripheral DevicesSelecting Heavy

Strona 20 - 2.4 Dimensions

3.3 Selecting Peripheral DevicesYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 27Table 3.2 400 V Class Input FuseNote: These f

Strona 21 - Front Cover

3.3 Selecting Peripheral Devices28 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual◆ Wiring PrecautionsThe external interconnecti

Strona 22 - Figure 2.6

3.4 Wiring Main Circuit TerminalsYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 293.4 Wiring Main Circuit Terminals◆ Required W

Strona 23

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 3Table of ContentsI. PREFACE...

Strona 24 - W ARNING

3.4 Wiring Main Circuit Terminals30 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualTable 3.5 400 V Class Wire SizeNote: Cable s

Strona 25 - 3.2 Connection Diagram

3.4 Wiring Main Circuit TerminalsYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 31◆ Closed-Loop Connectors SizeYaskawa recommen

Strona 26 - ◆ Main Circuit Input Fuse

32 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual3.5 External Terminals3.5 External Terminals◆ Main Circuit Terminal FunctionsTa

Strona 27

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 334Operation4.1 SECTION SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 28 - ◆ Wiring Precautions

34 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual4.1 Section Safety4.1 Section SafetyW ARNING Only turn ON the input power suppl

Strona 29 - <1>

4.2 Checks Prior to Main Power ApplicationYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 354.2 Checks Prior to Main Power Appli

Strona 30

36 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual4.3 Setting the Power Supply Voltage Jumper 4.3 Setting the Power Supply Voltag

Strona 31 - ◆ Closed-Loop Connectors Size

4.4 Using the Digital OperatorYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 374.4 Using the Digital OperatorThis section descr

Strona 32

4.4 Using the Digital Operator38 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualTable 4.1 Key FunctionNote: Except diagrams, ke

Strona 33 - Operation

4.5 Digital Operator ModesYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 394.5 Digital Operator ModesThis section describes the

Strona 34

4 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual4. OPERATION...

Strona 35

4.5 Digital Operator Modes40 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual◆ Navigating Digital Operator ModesOnce the power re

Strona 36 - 4. Replace the front cover

4.5 Digital Operator ModesYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 41 Parameter Setting ExampleThe group level will be d

Strona 37 - Operation Mode Indicators

4.5 Digital Operator Modes42 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual◆ Operation ModeOperation mode is the mode in which

Strona 38 - Table 4.1 Key Function

4.6 Power On/Off SequenceYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 434.6 Power On/Off SequenceRefer to Figure 4.5 when bui

Strona 39 - 4.5 Digital Operator Modes

44 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual4.7 Run Command Selection4.7 Run Command SelectionThis section explains the two

Strona 40 - 4.5 Digital Operator Modes

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 455Maintenance andInspection5.1 SECTION SAFETY . . . . . . . . . . . . . . . . . .

Strona 41

46 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual5.1 Section Safety5.1 Section SafetyW ARNING Never touch high-voltage terminals

Strona 42 - ◆ Operation Mode

5.2 Periodic Inspection and Maintenance YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 475.2 Periodic Inspection and Maintenanc

Strona 43 - 4.6 Power On/Off Sequence

5.2 Periodic Inspection and Maintenance 48 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualThis page intentionally blank.

Strona 44 - 4.7 Run Command Selection

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 496Troubleshooting6.1 FAULT DETECTION . . . . . . . . . . . . . . . . . . . . . .

Strona 45 - Inspection

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 3iPrefaceYASKAWA’s RC5 is a power regenerative unit which has both braking and reg

Strona 46

50 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual6.1 Fault Detection6.1 Fault DetectionWhen the power regenerative unit detects

Strona 47 - ◆ Periodic Inspection

6.1 Fault DetectionYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 51OLInput Over LoadedPower Regenerative Unit Input OverloadPo

Strona 48

52 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual6.2 Minor Fault Detection6.2 Minor Fault DetectionMinor faults are a type of th

Strona 49 - Troubleshooting

6.3 Operation ErrorsYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 536.3 Operation ErrorsAfter the parameters have been set, an

Strona 50 - 6.1 Fault Detection

6.3 Operation Errors54 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualThis page intentionally blank.

Strona 51 - 6.1 Fault Detection

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 557Specifications

Strona 52 - 6.2 Minor Fault Detection

56 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualNote: 1. Consult the factory if connecting more than one inverter to one powe

Strona 53 - 6.3 Operation Errors

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 57Table 7.2 400 V Class SpecificationsNote: Use a power regenerative unit with l

Strona 54 - 6.3 Operation Errors

58 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualThis page intentionally blank.

Strona 55 - Specifications

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 59AParameter List

Strona 56

4 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manuali.1 Conditions of Acceptabilityi.1 Conditions of Acceptability◆ NEC, CEC and UL

Strona 57

60 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualTable A.1 shows the items that can be monitored in operation mode. The output

Strona 58

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 61Fault TraceU2-01Current faultInformation on the current fault(Cannot be output)

Strona 59 - Parameter List

62 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualTable A.2 Parameter ListParameter No.Parameter NameSetting RangeFactory Sett

Strona 60 - U1-12 = 00000000

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 63H4-01Multi-function AO (terminal AM-AC)0 to 21 5 O ASelects which monitor will

Strona 61

64 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manualo1-02Monitor selection after power up2 to 4 2 O ASelects which monitor will b

Strona 62

YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 65Table A.3 Multi-function Input FunctionsTable A.4 Multi-function Output Funct

Strona 63

66 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction ManualTable A.5 Multi-function Analog Output FunctionsSetting value Function (H4-0

Strona 64

Revision HistoryDocument revision dates and revision numbers are provided on the bottom of the back cover.Date of Publication Rev. No. Section Revised

Strona 66

YASKAWA AMERICA, INC.2121 Norman Drive South, Waukegan, IL 60085, U.S.A.Phone: (800) YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310http://

Strona 67 - Revision History

i.2 Safety InformationYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 5i.2 Safety InformationRead this instruction manual thorou

Strona 68

6 YASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manuali.3 Notes for Safe Operationi.3 Notes for Safe Operation◆ Receiving◆ Installatio

Strona 69

i.3 Notes for Safe OperationYASKAWA ELECTRIC TOEP C710656 01C YASKAWA - RC5 Instruction Manual 7◆ Operation◆ Maintenance and InspectionW ARNING Onl

Komentarze do niniejszej Instrukcji