INTRODUCTION
The Isolated Monitor Card CM-B2/P is mounted on the control board of a VS-616PC5 or P5 inverter,
and is used to convert the inverter’s analog monitor signals (0 to 10V) to an isolated configurable sig-
nal. This option card can be used on any of the VS-616PC5/P5 Series inverters. When purchasing an
option card, please specify the inverter model and code number.
Description
NAME CODE NUMBER FUNCTIONS
Isolated Monitor Card
CM-B2/P
73600-DO12X Converts analog monitor signals (0 to 10V) to isolated signals
(0 to 10V, 4 to 20mA or 0 to 20mA).
CM-B2/P
73600-DO120
Grounding lead wire (connected
to terminal E (G) of inverter
control board
E
Terminal block TB1 for
isolated signal output
Analog monitor signals (0 to 10V) input
lead wire connected to terminals AM and
CM of inverter control board
Fig. 1 Isolated Monitor Card CM-B2/P
TB1
12
TB2
CODE NO.
HRD1
Connector to inverter control
board (2CN)