Yaskawa YASNAC PC NC Maintenance Manual Instrukcja Użytkownika Strona 55

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 54
PC NC Maintenance Manual Chapter 4: Troubleshooting
4-34
VS-626MR5 Alarm List
In the VS-626MR5, the protective functions operate according to the error
content when a fault and an error phenomenon are generated during a drive
operation when the drive is stopped. This error content is displayed on the
7 segment LED, according to alarm number.
Table 4.17: Alarm List
Alarm
Number
Name Content
01 Overcurrent Output current flowed more than the overcurrent detection level.
04 Main circuit fuse is blown Main circuit fuse is blown.
05 Overload Output current exceeded the overload level.
11 Output overvoltage Output voltage exceeded the overvoltage setting value.
12 Main circuit low voltage Main circuit input voltage went below the low voltage detection level
while driving.
13 Control circuit low voltage Control circuit power supply went below the low voltage detection
level.
14 Power failure for servo
driver
Control voltage supplied to the servo driver is abnormal.
15 Power supply frequency
error
Power supply frequency excessive deviation (50Hz or 60Hz±6%)
16 An initial charge defect Main circuit condenser charge was not completed in the setting time.
23 Built-in MC defective per-
formance
Magnetic contactor does not work.
43 Heat sink over heating 1
(minor fault)
Heat sink temperature exceeded the upper limit.
44 Heat sink overheating 2 Heat sink temperature exceeded the upper limit and has passed one
minute or more.
45 Heat sink thermistor dis-
connection
Thermistor for the heat sink temperature detection was discon-
nected.
46 Control card temperature
error (minor fault)
Control card temperature exceeded +80ºC.
47 Control card temperature
error 2
Control card temperature exceeded +85ºC.
d2 CPU built-in A/D defective Built-in A/D converter is defective.
F0 ROM defect Memory (PROM) is defective.
F1 EEPROM defect Memory (EEPROM) is defective.
F5 CPU defect Internal RAM check error (at initialization).
• • Control card fault WDT time-out
Przeglądanie stron 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 300 301

Komentarze do niniejszej Instrukcji