YASKAWA SERVO Instrukcja Użytkownika Strona 83

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 109
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 82
3.3 Main Circuit Wiring
3-29
3
Wiring and Connection
Wiring Procedure
1. Remove the main circuit terminal connector from the SERVOPACK.
2. Strip the end of the wires.
3. Open the wire terminal on the terminal connector housing with a tool,
using the following methods. Either method can be used to open the
wire terminal.
Using a spring opener
Use the spring opener provided with the SERVOPACK to open the wire terminal as
shown in the diagram.
Note: The spring opener (1981045-1) made by Tyco Electronics AMP K.K. can also be used.
Main circuit
terminal connector
Enlarged View
Lock
1Press
the lock.
2. Remove the main
circuit terminal
connector while
pressing the lock.
Applicable wire sizes:
8 to 9 mm
Refer to 3.3.2 SERVOPACK
Main Circuit Wire Size.
Wire
Spring opener
Przeglądanie stron 82
1 2 ... 78 79 80 81 82 83 84 85 86 87 88 ... 108 109

Komentarze do niniejszej Instrukcji

Brak uwag