YASKAWA NX100 Instrukcja Operatora

Przeglądaj online lub pobierz Instrukcja Operatora dla System spawalniczy YASKAWA NX100. YASKAWA NX100 Operator`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 297
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - INFORM MANUAL

YASKAWAYASKAWA MANUAL NO. RE-CKI-A444NX100INFORM MANUALUpon receipt of the product and prior to initial operation, read these instructions thoroughly,

Strona 2 - MANDATORY

1.1 About INFORM1-21.1.3 Instruction SetTo improve operation efficiency, the number of instructions to be registered is limited. All instructions are

Strona 3 - PROHIBITED

2.3 Operating Instruction2-78(1) SUB B000 10Subtracts 10 from B000, and stores the result in B000.(2) SUB I000 I001Subtracts I001 from I000, and stor

Strona 4 - Emergency Stop Button

2.3 Operating Instruction2-79MULInstruction set:Multiplies Data 1 by Data 2, and stores the result in Data 1.MUL <Data 1> <Data 2>SUBSE

Strona 5 - NX100 Controller NX100

2.3 Operating Instruction2-80B/LB/B[]/LB[]Variable No.I/LI/I[]/LI[]Variable No.D/LD/D[]/LD[]Variable No.R/LR/R[]/LR[]Variable No.Byte typeconstantInt

Strona 6

2.3 Operating Instruction2-811. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/I Variable number/LI Variable number/I [Arra

Strona 7 - 2 INFORM Explanation

2.3 Operating Instruction2-826BP Variable num-ber/LBP Variable number/BP [Array num-ber]/LBP [Array num-ber]Specifies the number of the base axis pos

Strona 8

2.3 Operating Instruction2-832. Byte type constant/B Variable number/LB Variable number/B [Array num-ber]/LB [Array number]/I Variable number/LI Vari

Strona 9 - 1 INFORM Manual Outline

2.3 Operating Instruction2-843. Integer type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable number/LI Va

Strona 10 - 1.1.3 Instruction Set

2.3 Operating Instruction2-854. Double-precision type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable num

Strona 11 - MainMenu ShortCut

2.3 Operating Instruction2-865. Real-number type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable number/L

Strona 12 - 1.2.1 Registration

2.3 Operating Instruction2-876. (Element number)When a P Variable number, LP Variable number, P [Array number], LP [Array number], BP Variable number

Strona 13 - 1.2.2 Learning Function

1.1 About INFORM1-31.1.4 Variables to be Used in InstructionsVariables can be used as numeric data for the additional item of the instructions in the

Strona 14 - Operation Explanation

2.3 Operating Instruction2-887. D Variable number/LD Variable number/D [Array number]/LD [Array num-ber]/ Double-precision type constantWhen a P Vari

Strona 15 - 1.3 Detail Edit Window

2.3 Operating Instruction2-89DIVInstruction set:Divides Data 1 by Data 2, and stores the result in Data 1.DIV <Data 1> <Data 2>SUBSET S

Strona 16 - 1.4.1 Expression

2.3 Operating Instruction2-90B/LB/B[]/LB[]Variable No.I/LI/I[]/LI[]Variable No.D/LD/D[]/LD[]Variable No.R/LR/R[]/LR[]Variable No.Byte typeconstantInt

Strona 17 - ) )) )))

2.3 Operating Instruction2-911. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/I Variable number/LI Variable number/I [Arra

Strona 18 - 1.4.2 Registration

2.3 Operating Instruction2-926BP Variable num-ber/LBP Variable number/BP [Array num-ber]/LBP [Array num-ber]Specifies the number of the base axis pos

Strona 19 - Main Menu Short Cut

2.3 Operating Instruction2-932. Byte type constant/B Variable number/LB Variable number/B [Array num-ber]/LB [Array number]/I Variable number/LI Vari

Strona 20 - 1.5 INFORM Structure

2.3 Operating Instruction2-943. Integer type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable number/LI Va

Strona 21 -  Meaning of INFORM Structure

2.3 Operating Instruction2-954. Double-precision type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable num

Strona 22 -  Explanation Table

2.3 Operating Instruction2-965. Real-number type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable number/L

Strona 23 - 2 INFORM Explanation

2.3 Operating Instruction2-976. (Element number)When a P Variable number, LP Variable number, P [Array number], LP [Array number], BP Variable number

Strona 24 - OGH#(1)OGH#(2)

1.2 Registration of Instructions1-4< Example > TIMER tag (T=)TIMER T=I000When a variable is used for the numeric data of the TIMER tag, the uni

Strona 25 - OT#(17)OT#(23) OT#(22)

2.3 Operating Instruction2-98CNVRTInstruction set:Converts the pulse type position type variable of Data 2 to the XYZ type position type variable in

Strona 26

2.3 Operating Instruction2-992. PX Variable number/LPX Variable number/PX [Array number]/LPX [Array number]Add the following tag.Expanded position ty

Strona 27 - IGH#(1)IGH#(2)

2.3 Operating Instruction2-1003. BF/RF/TF/UF# (User coordinate number)/MTFChoose one of the tags from the following table.CNVRT PX000 PX001 BFFor the

Strona 28 - 2.1 I/O Instructions

2.3 Operating Instruction2-101ANDInstruction set:Carries out logical multiplication of Data 1 and Data 2, and stores the result in Data 1.AND <Da

Strona 29

2.3 Operating Instruction2-1022. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/Byte type constantChoose one of the tags fr

Strona 30

2.3 Operating Instruction2-103ORInstruction set:Carries out the logical sum of Data 1 and Data 2, and stores the result in Data 1.OR <Data 1>

Strona 31

2.3 Operating Instruction2-1042. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/Byte type constantChoose one of the tags fr

Strona 32

2.3 Operating Instruction2-105NOTInstruction set:Carries out the logical negation of Data 2, and stores the result in Data 1.NOT <Data 1> &l

Strona 33

2.3 Operating Instruction2-1062. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/Byte type constantChoose one of the tags fr

Strona 34

2.3 Operating Instruction2-107XORInstruction set:Carries out the logical exclusive OR of Data 1 and Data 2, and stores the result in Data 1.XOR <

Strona 35

1.2 Registration of Instructions1-51.2.2 Learning FunctionWith the learning function, an instruction can be registered with the same additional items

Strona 36 - Pulse signal

2.3 Operating Instruction2-1082. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/Byte type constantChoose one of the tags fr

Strona 37 - Output voltage

2.3 Operating Instruction2-109MFRAMEInstruction set:Creates the user coordinates according to three types of position data; Data 1, Data 2, and Data

Strona 38

2.3 Operating Instruction2-1102. PX Variable number/LPX Variable number/PX [Array number]/LPX [Array number]Add the following tag.3. PX Variable numb

Strona 39 - 4. OFV=Offset voltage

2.3 Operating Instruction2-111MFRAME UF#(1) PX000 PX001 PX002For the job R1, the user coordinate number 1 is created according to three types of posi

Strona 40 - Offset voltage

2.3 Operating Instruction2-112SETEInstruction set:Sets Data 2 in the element of position type variable of Data 1.SETE <Data 1> (Element numbe

Strona 41

2.3 Operating Instruction2-1131. P Variable number/LP Variable number/P [Array number]/LP [Array num-ber]/BP Variable number/LBP Variable number/BP [

Strona 42

2.3 Operating Instruction2-1143. Double-precision type constant/D Variable number/LD Variable number/D [Array number]/LD [Array number]Choose one of

Strona 43

2.3 Operating Instruction2-115GETEInstruction set:Stores the element of position type variable of Data 2 in Data 1.GETE <Data 1> <Data 2&g

Strona 44

2.3 Operating Instruction2-1162. P Variable number/LP Variable number/P [Array number]/LP [Array num-ber]/BP Variable number/LBP Variable number/BP [

Strona 45

2.3 Operating Instruction2-117GETSInstruction set:Stores the system variable of Data 2 in Data 1.GETS <Data 1> <Data 2>SUBSET STANDARD

Strona 46

1.2 Registration of Instructions1-64Press [SELECT]The condition “VALID” or “INVALID” is switchable each time [SELECT] is pressed. Operation Explana

Strona 47

2.3 Operating Instruction2-1181. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/I Variable number/LI Variable number/I [Arr

Strona 48 - 2.2 Control Instruction

2.3 Operating Instruction2-119System variableThe system variables are written by the controller system and can be referred only by a GETS instruction

Strona 49

2.3 Operating Instruction2-120ContinuedSystem VariableType No. Explanation$PX type variableExpanded position type$PX000 Current value (pulse type)$P

Strona 50

2.3 Operating Instruction2-1212. $B Variable number/$B [Array number]When a B Variable number, LB Variable number, B [Array number], or LB [Array num

Strona 51

2.3 Operating Instruction2-1224. $D Variable number/$D [Array number]When a D Variable number, LD Variable number, D [Array number], or LD [Array num

Strona 52 - Calls the specified job

2.3 Operating Instruction2-123SQRTInstruction set:Calculates the square root of Data 2, and stores the result in Data 1.SQRT <Data 1> <Dat

Strona 53

2.3 Operating Instruction2-1242. R Variable number/LR Variable number/R [Array number]/LR [Array num-ber]/Real-number type constantChoose one of the

Strona 54

2.3 Operating Instruction2-125SINInstruction set:Calculates the sine of Data 2, and stores the result in Data 1.SIN <Data 1> <Data 2>1.

Strona 55

2.3 Operating Instruction2-1262. R Variable number/LR Variable number/R [Array number]/LR [Array num-ber]/Real-number type constantChoose one of the

Strona 56 - * (LABEL)

2.3 Operating Instruction2-127COSInstruction set:Calculates the cosine of Data 2, and stores the result in Data 1.COS <Data 1> <Data 2>

Strona 57 - ’ (COMMENT)

1.3 Detail Edit Window1-71.3 Detail Edit WindowAll instructions have a detail edit window.The detail edit window is used for adding, modifying, and d

Strona 58

2.3 Operating Instruction2-1282. R Variable number/LR Variable number/R [Array number]/LR [Array num-ber]/Real-number type constantChoose one of the

Strona 59 - Carries out no operation

2.3 Operating Instruction2-129ATANInstruction set:Calculates the arc tangent of Data 2, and stores the result in Data 1.ATAN <Data 1> <Dat

Strona 60

2.3 Operating Instruction2-1302. R Variable number/LR Variable number/R [Array number]/LR [Array num-ber]/Real-number type constantChoose one of the

Strona 61 - CWAIT END

2.3 Operating Instruction2-131MULMATInstruction set:Calculates the matrix multiplication of Data 2 and Data 3, and stores the result in Data 1.MULMAT

Strona 62

2.3 Operating Instruction2-1322. P Variable number/LP Variable number/P [Array number]/LP [Array num-ber]Add the following tag.3. P Variable number/L

Strona 63

2.3 Operating Instruction2-133MOVL P010 V=500GETS PX020 $PX001:INVMAT P021 P010:MULMAT P023 P020 P021:Stores the current XYZ type value in P020.Calcu

Strona 64 - 2.3 Operating Instruction

2.3 Operating Instruction2-134INVMATInstruction set:Calculates the inverse matrix of Data 2, and stores the result in Data 1.INVMAT <Data 1>

Strona 65

2.3 Operating Instruction2-135MOVL P010 V=500GETS PX020 $PX001:INVMAT P021 P010:MULMAT P023 P020 P021:Stores the current XYZ type value in P020.Calcu

Strona 66

2.3 Operating Instruction2-136SETFILEInstruction set:Changes the specified data of the specified condition file to the numeric data of Data 1.Specify

Strona 67

2.3 Operating Instruction2-1371. SPR# (Sealing adjustment condition file number)/UDC# (Under-coating adjustment condition file number)/WEV# (Weaving

Strona 68

1.4 Registration of Expression1-81.4 Registration of Expression1.4.1 ExpressionWith INFORM II, an expression can be added to the SET instruction.<

Strona 69

2.3 Operating Instruction2-1383. Double-precision type constant/D Variable number/LD Variable number/D [Array number]/LD [Array number]Choose one of

Strona 70

2.3 Operating Instruction2-139SETFILE WEV#(1) (5) 3500Changes the amplitude setting in the weaving condition file number 1 to 3.500 mm.Element number

Strona 71

2.3 Operating Instruction2-140GETFILEInstruction set:Stores the data of the specified condition file in Data 1.Specify the data of the condition file

Strona 72 - Sets Data 2 to Data 1

2.3 Operating Instruction2-1412. SPR# (Sealing adjustment condition file number)/UDC# (Under-coating adjustment condition file number)/WEV# (Weaving

Strona 73

2.4 Move Instruction2-1422.4 Move InstructionMOVJInstruction set:Moves to the teaching position by joint interpolation. The tag which can be used is

Strona 74

2.4 Move Instruction2-143Job Type and Control GroupNo. Job Type Control Group Remarks1 Single One manipulator (standard)2 Single One manipulator with

Strona 75

2.4 Move Instruction2-144

Strona 76

2.4 Move Instruction2-1451. Robot teaching position file number /P Variable number /LP Variable num-ber /P [Array number] /LP [Array number] /Station

Strona 77

2.4 Move Instruction2-1462. Base Teaching Position File NumberWhen a robot teaching position file number is selected from the table in part 1 of this

Strona 78

2.4 Move Instruction2-1476. EX Variable number /LEX Variable number /EX [Array number] /LEX [Array number] When a P Variable number, LP Variable numb

Strona 79

1.4 Registration of Expression1-9DataThe data type of the expression is indicated. The following types of data can be registered.• Constant (byte t

Strona 80

2.4 Move Instruction2-1489. PL=Position level /SPDL=Speed levelChoose one of the tags from the following table.No Tag Explanation Note12PL=Position l

Strona 81 - (2) SET P000 P001

2.4 Move Instruction2-14910. MT=Amount of the T axis rotationThe following tag can be added or omitted. 11. MTE= Amount of the station axis rotation

Strona 82

2.4 Move Instruction2-15013. UNTIL/NSRCHChoose one of the tags from the following table.14. ACC=Acceleration adjustment ratioThe following tag can be

Strona 83

2.4 Move Instruction2-15116. +MOVJ/+MOVL/+MOVC/+MOVSChoose one of the tags from the following table.Acceleration adjustment ratioThe acceleration adj

Strona 84

2.4 Move Instruction2-152MOVJ P000 VJ=50.00Move from the manipulator’s waiting position to step 1. Move by joint interpolation at a speed of 50%. The

Strona 85

2.4 Move Instruction2-153MOVLInstruction set:Moves to the teaching position by linear interpolation. The tag which can be used is limited by the type

Strona 86

2.4 Move Instruction2-154Job Type and Control GroupNo. Job Type Control Group Remarks1 Single One manipulator (standard)2 Single One manipulator with

Strona 87

2.4 Move Instruction2-155

Strona 88

2.4 Move Instruction2-1561. Robot teaching position file number /P Variable number /LP Variable num-ber /P [Array number] /LP [Array number] Choose o

Strona 89

2.4 Move Instruction2-1574. T Point Variable numberWhen the robot teaching position file number is selected from the table in part 1 of this Expla-na

Strona 90

1.4 Registration of Expression1-10< Example of the DETAIL EDIT display for expression >1.4.2 RegistrationOperation Explanation1 Select {JOB} un

Strona 91

2.4 Move Instruction2-1587. V=Tool center point speed /VR=Position angular speed /VE=External axis speedChoose one of the tags from the following tab

Strona 92

2.4 Move Instruction2-1598. PL=Position level /CR=Corner radius /SPDL=Speed levelChoose one of the tags from the following table.No Tag Explanation N

Strona 93

2.4 Move Instruction2-1609. MTE= Amount of station axis rotationThe following tag can be added or omitted. 10. NWAIT/ENWAITThe following tag can be

Strona 94

2.4 Move Instruction2-16111. SRCH/UNTIL/ASRCH/HPSRCH/NSRCHChoose one of the tags from the following table.12. ACC=Acceleration adjustment ratioThe fo

Strona 95

2.4 Move Instruction2-16213. DEC=Deceleration adjustment ratioThe following tag can be added or omitted. 14. +MOVJ/+MOVL/+MOVC/+MOVSChoose one of th

Strona 96

2.4 Move Instruction2-163NOPMOVJ VJ=50.00MOVJ VJ=25.00MOVJ VJ=12.50    Step 3 MOVL V=138    Step 4 Moves from Step 3 to Step 4 b

Strona 97

2.4 Move Instruction2-164MOVCInstruction set:Moves to the teaching position by circular interpolation. The tag which can be used is limited by the ty

Strona 98

2.4 Move Instruction2-165Job Type and Control GroupNo. Job Type Control Group Remarks1 Single One manipulator (standard)2 Single One manipulator with

Strona 99

2.4 Move Instruction2-166 Availability of Each TagNo TagControl GroupNote1234561

Strona 100 - 2.3 Operating Instruction

2.4 Move Instruction2-1671. Robot teaching position file number /P Variable number /LP Variable num-ber /P [Array number] /LP [Array number] Choose o

Strona 101 - Instruction set:

1.4 Registration of Expression1-11Operation Explanation7 Move the cursor to the button beside “SOURCE(TOKEN)”8 Press [SELECT] The selection dialog b

Strona 102

2.4 Move Instruction2-1684. T Point Variable numberWhen the robot teaching position file number is selected from the table in part 1 of this Expla-na

Strona 103

2.4 Move Instruction2-1697. V=Tool center point speed /VR=Position angular speed /VE=External axis speedChoose one of the tags from the following tab

Strona 104

2.4 Move Instruction2-1709. MTE=Amount of station axis rotationThe following tag can be added or omitted. 10. NWAIT/ENWAITThe following tag can be a

Strona 105

2.4 Move Instruction2-17112. DEC=Deceleration adjustment ratioThe following tag can be added or omitted.13. +MOVJ/+MOVL/+MOVC/+MOVSChoose one of the

Strona 106

2.4 Move Instruction2-172NOPMOVL V=138MOVC V=138    Step 2MOVC V=138    Step 3MOVC V=138    Step 4MOVC V=138    Step 5MOV

Strona 107

2.4 Move Instruction2-173MOVSInstruction set:Moves to the teaching position by spline interpolation.The tag which can be used is limited by the type

Strona 108

2.4 Move Instruction2-174Job Type and Control GroupNo. Job type Control Group Remarks1 Single One manipulator (standard)2 Single One manipulator with

Strona 109 - 6. (Element number)

2.4 Move Instruction2-175 Availability of Each TagNo TagControl GroupNote1234561

Strona 110

2.4 Move Instruction2-1761. Robot teaching position file number /P Variable number /LP Variable num-ber /P [Array number] /LP [Array number] Choose o

Strona 111

2.4 Move Instruction2-1774. T Point Variable numberWhen the robot teaching position file number is selected from the table in part 1 of this Expla-na

Strona 112

ii• This manual explains the INFORM language of the NX100 system. Read this manual carefully and be sure to understand its contents before han-dlin

Strona 113

1.5 INFORM Structure1-121.5 INFORM Structure An example of the INFORM structure is shown in the following structure flowchart. The INFORM structure c

Strona 114

2.4 Move Instruction2-1787. V=Tool center point speed /VR=Position angular speed /VE=External axis speedChoose one of the tags from the following tab

Strona 115

2.4 Move Instruction2-1799. NWAIT/ENWAITThe following tag can be added or omitted. 10. ACC=Acceleration adjustment ratioThe following tag can be add

Strona 116

2.4 Move Instruction2-18012. +MOVJ/+MOVL/+MOVC/+MOVSChoose one of the tags from the following table.No Tag Explanation Note17+MOVJ Specifies the join

Strona 117

2.4 Move Instruction2-181NOP MOVL V=138 MOVS V=138    Step 2 MOVS V=138    Step 3 MOVS V=138

Strona 118

2.4 Move Instruction2-182IMOVInstruction set:Moves by linear interpolation from the current position for the specified incremental value. The tag whi

Strona 119

2.4 Move Instruction2-183Job Type and Control GroupNo. Job Type Control Group Remarks1 Single One manipulator (standard)2 Single One manipulator with

Strona 120 - Variable No

2.4 Move Instruction2-184 Availability of Each TagNo TagControl GroupNote12345671

Strona 121 - Add the following tag

2.4 Move Instruction2-1851. P Variable number /LP Variable number /P [Array number] /LP [Array num-ber] /EX Variable number /LEX Variable number /EX

Strona 122 - CNVRT PX000 PX001 BF

2.4 Move Instruction2-1863. VJ=Joint speedThe following tag can be added or omitted. 4. EX Variable number /LEX Variable number /EX [Array number] /L

Strona 123 - Byte type

2.4 Move Instruction2-1875. V=Tool center point speed /VR=Position angular speed /VE=External axis speed Choose one of the tags from the following ta

Strona 124

1.5 INFORM Structure1-13 INFORM Structure Elements Meaning of INFORM StructureINFORM Structure ElementExplanation NoteIndicates the instruction. I

Strona 125

2.4 Move Instruction2-1888. BF/RF/TF/UF# (User coordinate number)Choose one of the tags from the following table. 9. UNTIL/SRCH/NSRCHChoose one o

Strona 126

2.4 Move Instruction2-18910. ACC=Acceleration adjustment ratioThe following tag can be added or omitted.11. DEC=Deceleration adjustment ratioThe foll

Strona 127

2.4 Move Instruction2-190SPEEDInstruction set:Sets the playback speed. The manipulator operates at the speed specified in the SPEED instruction when

Strona 128

2.4 Move Instruction2-1911. VJ=Joint speedThe following tag can be added or omitted. 2. V=Tool center point speedThe following tag can be added or o

Strona 129

2.4 Move Instruction2-1924. VE=External axis speedThe following tag can be added or omitted.No Tag Explanation Note4VE=External axis speedSpecifies t

Strona 130

2.4 Move Instruction2-193REFPInstruction set:It is an instruction which has the position data by which a supplementary point of the wall point, etc.

Strona 131

2.4 Move Instruction2-194Job Type and Control GroupNo. Job Type Control Group Remarks1 Single One manipulator (standard)2 Single One manipulator with

Strona 132

2.4 Move Instruction2-1951. Reference Point NumberAdd the following tag.Availability of Each TagNo TagControl GroupNote1234567891 Reference point num

Strona 133

2.4 Move Instruction2-1962. RB1/RB2/RB3/ST1/ST2/ST3/ST4/ST5/ST6Choose one of the tags from the following table. Reference points during weavingUsual

Strona 134

2.4 Move Instruction2-1973. Robot teaching position file number /P Variable number /LP Variable num-ber /P [Array number] /LP [Array number] Choose o

Strona 135

1.5 INFORM Structure1-14 Explanation TableThe explanation table in this manual can be described as follows. • NO.Indicates the tag number. Corres

Strona 136 - SETE P000 (3) 2000

2.4 Move Instruction2-1986. BP Variable number /LBP Variable number /BP [Array number] /LBP [Array number] When a P Variable number, LP Variable numb

Strona 137

2.4 Move Instruction2-1998. Station teaching position file number/EX Variable number /LEX Variable number /EX [Array number] /LEX [Array number]Choos

Strona 138

2.5 Shift Instruction2-2002.5 Shift InstructionSFTONInstruction set:Begins the parallel shift operation. The amount of the parallel shift is set in a

Strona 139

2.5 Shift Instruction2-201Job Type and Control GroupNo. Job Type Control Group Remarks1 Single One manipulator (standard)2 Single One manipulator wit

Strona 140

2.5 Shift Instruction2-2021. RB1/RB2/RB3Choose one of the tags from the following table.2. P Variable number /LP Variable number /P [Array number] /L

Strona 141

2.5 Shift Instruction2-2033. BP Variable number /LBP Variable number /BP [Array number] /LBP [Array number] When a P Variable number, LP Variable num

Strona 142

2.5 Shift Instruction2-2045. BF/RF/TF/UF# (User coordinate number)When a P Variable number, LP Variable number, P [Array number], or LP [Array number

Strona 143

2.5 Shift Instruction2-205SFTOFInstruction set:Ends the parallel shift operation. The tags to be added are decided according to the type of the job.S

Strona 144

2.5 Shift Instruction2-2061. RB1/RB2/RB3/STChoose one of the tags from the following table.Shift between Step 3 and Step 5 in the user coordinate sys

Strona 145 - Real-number

2.5 Shift Instruction2-207MSHIFTInstruction set:Calculates the amount of the shift in the specified coordinate system according to Data 2 and Data 3

Strona 146 - SQRT R000 2

2.1 I/O Instructions2-12 INFORM Explanation2.1 I/O InstructionsDOUTInstruction set:Turns the general output signal on and off. 1. OT# (Output number)

Strona 147

2.5 Shift Instruction2-2081. PX Variable number/LPX Variable number/PX [Array number]/LPX [Array number]Add the following tag.2. BF/RF/TF/UF# (User c

Strona 148 - SIN R000 60

2.5 Shift Instruction2-2093. PX Variable number/LPX Variable number/PX [Array number]/LPX [Array number]Add the following tag.4. PX Variable number/L

Strona 149

2.6 Instruction Which Adheres to an Instruction2-2102.6 Instruction Which Adheres to an InstructionIFInstruction set:Evaluates the various conditions

Strona 150 - COS R000 60

2.6 Instruction Which Adheres to an Instruction2-211=B/LB/B[]/LB[]Variable No.ON/OFF7 89=<>B/LB/B[]/LB[]Variable No.Byte typeconstant11121310A

Strona 151

2.6 Instruction Which Adheres to an Instruction2-212=<>>>=<<=363738394041I JB/LB/B[]/LB[]Variable No.I/LI/I[]/LI[]Variable No.D/LD/

Strona 152 - ATAN R000 60

2.6 Instruction Which Adheres to an Instruction2-2131. IN# (Input number) /IG# (Input group number) /B Variable number /LB Vari-able number /B [Array

Strona 153 - Variable No.Variable No

2.6 Instruction Which Adheres to an Instruction2-2142. =When an IN#(Input number) is selected from the table in part 1 of this Explanation, add the f

Strona 154

2.6 Instruction Which Adheres to an Instruction2-2155. B Variable number /LB Variable number /B [Array number] /LB [Array num-ber] /ON /OFFWhen an IG

Strona 155

2.6 Instruction Which Adheres to an Instruction2-2167. Byte type constant /B Variable number /LB Variable number /B [Array number] /LB [Array number]

Strona 156 - INVMAT END

2.6 Instruction Which Adheres to an Instruction2-2178. =/<>/>/>=/</<=When an I Variable number, LI Variable number, I [Array number

Strona 157

2.1 I/O Instructions2-22. B Variable number /LB Variable number /B [Array number] /LB [Array num-ber] /ON /OFFWhen OT# (output number) is selected fr

Strona 158

2.6 Instruction Which Adheres to an Instruction2-2189. Integer type constant /B Variable number /LB Variable number /B [Array number] /LB [Array numb

Strona 159 - 2. (Element number)

2.6 Instruction Which Adheres to an Instruction2-21910. =/<>/>/>=/</<=When a D Variable number, LD Variable number, D [Array number

Strona 160

2.6 Instruction Which Adheres to an Instruction2-22011. Double precision type constant/ B Variable number /LB Variable number /B [Array number] /LB [

Strona 161 - SETFILE WEV#(1) (5) 3500

2.6 Instruction Which Adheres to an Instruction2-22112. =/<>/>/>=/</<=When an R Variable number, LR Variable number, R [Array numbe

Strona 162 - D/LD/D[]/

2.6 Instruction Which Adheres to an Instruction2-22213. Real type constant /B Variable number /LB Variable number /B [Array number] /LB [Array number

Strona 163

2.6 Instruction Which Adheres to an Instruction2-223UNTILInstruction set:Evaluates the input conditions during operation. This instruction is added

Strona 164 - 2.4 Move Instruction

2.6 Instruction Which Adheres to an Instruction2-2243. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/ON/OFF. Choose one o

Strona 165 - Job Type and Control Group

2.6 Instruction Which Adheres to an Instruction2-225ENWAITThe ENWAIT instruction can be used only with parameter S2C576.Instruction set:Carries out,

Strona 166 - Availability of Each Tag

2.7 Arc Welding Instruction2-2262.7 Arc Welding InstructionARCONFor arc welding applicationsInstruction set:Outputs the welding start command. SUBSET

Strona 167 - LEX [Array number]

2.7 Arc Welding Instruction2-2271. WELD1/WELD2/WELD3/WELD4Choose one of the tags from the following table. These tags are valid for a system with mul

Strona 168

2.1 I/O Instructions2-3number] / Byte type constantWhen OG# (Output group number) or OGH# (Output group number) is selected from the table in part 1

Strona 169

2.7 Arc Welding Instruction2-2284. T=TimeWhen AC=Current output value is selected from the table in part 2 of this Explanation, the fol-lowing tag ca

Strona 170

2.7 Arc Welding Instruction2-229RETRY functionThe RETRY function performs the arc retry automatically with a condition set in the auxil-iary conditio

Strona 171

2.7 Arc Welding Instruction2-230(1) ARCON ASF#(1)Starts welding with the condition set to No.1 in the arc start condition file. (2) NOPMOVJ VJ=50.00M

Strona 172

2.7 Arc Welding Instruction2-231ARCOFFor arc welding applicationsInstruction set:Outputs welding end command. 1. WELD1/WELD2/WELD3/WELD4Choose one of

Strona 173 - 16. +MOVJ/+MOVL/+MOVC/+MOVS

2.7 Arc Welding Instruction2-2322. AEF# (Arc end condition file number) /AC=Current output valueChoose one of the tags from the following table.3. AV

Strona 174 - MOVJ P000 VJ=50.00

2.7 Arc Welding Instruction2-2335. ANTSTKWhen AC=Current output value is selected from the table in part 2 of this Explanation, the fol-lowing tag ca

Strona 175

2.7 Arc Welding Instruction2-234(1) ARCOF AEF#(1)The welding end condition is set in the arc end condition file No.1. (2) NOPMOVJ VJ=50.00MOVL V=220M

Strona 176

2.7 Arc Welding Instruction2-235VWELDFor arc welding applicationsInstruction set:Sets the arc voltage by the voltage command value. 1. WELD1 /WELD2/W

Strona 177

2.7 Arc Welding Instruction2-2362. Voltage command value /I Variable number /LI Variable number /I [Array number] /LI [Array number]Choose one of the

Strona 178

2.7 Arc Welding Instruction2-237AWELDFor arc welding applicationsInstruction set:Sets the welding current by the current command position. 1. WELD1/W

Strona 179

2.1 I/O Instructions2-4DINInstruction set:Refers to the byte type variable for the status of the signal. 1. B Variable Number / LB Variable Number /

Strona 180

2.7 Arc Welding Instruction2-2382. Current command value /I Variable number /LI Variable number /I [Array number] /LI [Array number]Choose one of the

Strona 181 - Corner radius

2.7 Arc Welding Instruction2-239ARCSETFor arc welding applicationsInstruction set:Sets and changes each welding condition individually.SUBSET STANDAR

Strona 182

2.7 Arc Welding Instruction2-2401. WELD1/WELD2/WELD3/WELD4Choose one of the tags from the following table. These tags are valid for a system with mu

Strona 183

2.7 Arc Welding Instruction2-2414. V=Welding speedThe following tag can be added or omitted. 5. AN3=Aimed value of instruction voltage The following

Strona 184 - 14. +MOVJ/+MOVL/+MOVC/+MOVS

2.7 Arc Welding Instruction2-242NOPMOVJ VJ=50.00MOVJ VJ=80.00ARCON AC=200 AVP=100 T=0.30MOVL V=50MOVL V=50ARCSET AC=250MOVL V=65ARCOFMOVJ VJ=50.00MOV

Strona 185

2.7 Arc Welding Instruction2-243WVONFor arc, general-purpose, and laser welding applicationsInstruction set:Starts weaving operation.The tags to be a

Strona 186

2.7 Arc Welding Instruction2-2441. RB1/RB2/RB3/RB4Choose one of the tags from the following table. Availability of Each TagNo TagControl GroupNote12

Strona 187

2.7 Arc Welding Instruction2-2452. WEV# (Weaving condition file number)/AMP=Weaving single amplitudeChoose one of the tags from the following table.

Strona 188

2.7 Arc Welding Instruction2-2465. DIR=Direction of oscillationThe following tag can be added or omitted. No. Tag Explanation Note9DIR=Direction of

Strona 189

2.7 Arc Welding Instruction2-247Wearing conditions• Weaving single amplitudeSet the amplitude of oscillation.• Weaving angleSet the angle of oscillat

Strona 190

2.1 I/O Instructions2-52. IN#(Input number) / IG#(Input group number) / OT#(Output number) /OG#(Output group number) / SIN#(Specific input number) /

Strona 191

2.7 Arc Welding Instruction2-248(1) WVON WEV#(1) DIR=1Weaving starts with the conditions specified in the weaving condition file. For details of the

Strona 192

2.7 Arc Welding Instruction2-249WVOFFor arc, general-purpose, and laser welding applicationsInstruction set:Ends weaving operation.The tags to be add

Strona 193 - 13. +MOVJ/+MOVL/+MOVC/+MOVS

2.7 Arc Welding Instruction2-2501. RB1/RB2/RB3/RB4Choose one of the tags from the following table.No Tag Explanation Note1RB1 Specifies Robot 1 to en

Strona 194

2.7 Arc Welding Instruction2-251ARCCTSFor arc welding applicationsInstruction set:Controls the welding current and the voltage in the specified start

Strona 195

2.7 Arc Welding Instruction2-2521. WELD1/WELD2/WELD3/WELD4Choose one of the tags from the following table. These tags are valid for a system with mul

Strona 196

2.7 Arc Welding Instruction2-2534. AN3=Aimed value of instruction voltageThe following tag can be added or omitted.5. AN4=Aimed value of instruction

Strona 197

2.7 Arc Welding Instruction2-254(1) ARCCTS AC=150 AV=16.0 DIS=100.0MOVL V=80To make the welding current =150A and arc voltage =16V, the current and t

Strona 198

2.7 Arc Welding Instruction2-255ARCCTEFor arc welding applicationsInstruction set:Controls the welding current and the voltage in the specified end s

Strona 199

2.7 Arc Welding Instruction2-2561. WELD1 /WELD2/WELD3/WELD4Choose one of the tags from the following table. These tags are valid for a system with mu

Strona 200

2.7 Arc Welding Instruction2-2574. AN3=Aimed value of instruction voltageThe following tag can be added or omitted. 5. AN4=Aimed value of instructi

Strona 201

2.1 I/O Instructions2-6(1) DIN B016 IN#(12)The on/off status of general input signal no.12 is shown in byte type variable No.16. When the general inp

Strona 202 - 12. +MOVJ/+MOVL/+MOVC/+MOVS

2.7 Arc Welding Instruction2-258(1) ARCCTE AC=150 AV=16.0 DIS=100.0MOVL V=80To make the welding current =150A and arc voltage =16V, the current and t

Strona 203 - 2.4 Move Instruction

2.8 Handling Instruction2-2592.8 Handling InstructionHANDFor handling applicationsInstruction set: Turns the signal to the tool valve ON or OFF to

Strona 204

2.8 Handling Instruction2-2602. Hand numberAdd the following tag.3. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/ON/OFFCh

Strona 205

2.8 Handling Instruction2-261HSENFor handling applicationsInstruction set:Monitors the input status of the tool sensor. Stores the result in the sys

Strona 206

2.8 Handling Instruction2-2622. Sensor numberAdd the following tag.3. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/ON/OFF

Strona 207

2.9 Spot Welding Instruction2-2632.9 Spot Welding InstructionGUNCLFor spot welding applicationsInstruction set:Applies pressure to the air gun. 1. GU

Strona 208

2.9 Spot Welding Instruction2-2643. ATT= Anticipation timeThe following tag can be added or omitted. MOVL V=1000 NWAIT   

Strona 209

2.9 Spot Welding Instruction2-265SPOTFor spot welding applicationsInstruction set:Starts the welding sequence after pressure has been applied to the

Strona 210 - 9. UNTIL/SRCH/NSRCH

2.9 Spot Welding Instruction2-2662. MODE=Gun 1 operation modeAdd the following tag.3. WTM=Gun 1 welding conditionAdd the following tag.No. Tag Explan

Strona 211

2.9 Spot Welding Instruction2-2674. GUN# (Gun 2 number)The following tag can be added or omitted.5. MODE=Gun 2 operation modeWhen a Gun 2 number (GUN

Strona 212 - ×: Not available

2.1 I/O Instructions2-7WAITInstruction set:Waits until the status of the external signal or byte type variable is the same as the specified status. S

Strona 213

2.9 Spot Welding Instruction2-2687. ATT=Anticipation timeThe following tag can be added or omitted.MOVL V=1000 NWAIT

Strona 214

2.9 Spot Welding Instruction2-269STROKEFor spot welding applicationsInstruction set: Switches the open status of the 2-step stroke gun to/from Full o

Strona 215

2.9 Spot Welding Instruction2-270STRWAITFor spot welding applicationsInstruction set: Confirms the specified open status of a 2-step stroke gun as sh

Strona 216

2.9 Spot Welding Instruction2-271MOVL V=1000 NWAIT  Step 5STROKE GUN#(1) LONGSTRWAIT GUN#(1) LONGWhen the manipulator reaches Step 5, the ope

Strona 217 - 1. Reference Point Number

2.10 General-purpose Instruction2-2722.10 General-purpose InstructionTOOLONFor general-purpose applicationsInstruction set:Turns ON the work instruct

Strona 218 - REFP1 REFP2

2.10 General-purpose Instruction2-273TOOLONTurns ON the work instruction.Turns ON the work start instruction (dedicated output relay #50770) and wait

Strona 219

2.10 General-purpose Instruction2-274TOOLOFFor general-purpose applicationsInstruction set:Turns OFF the work instruction.1. TOOL1/TOOL2/TOOL3Choose

Strona 220

YASKAWAYASKAWA ELECTRIC CORPORATIONSpecifications are subject to change without noticefor ongoing product modifications and improvements.MANUAL NO. RE

Strona 221 - Wall direction

iiiNOTES FOR SAFE OPERATIONRead this manual carefully before installation, operation, maintenance, or inspection of the NX100. In this manual, the Not

Strona 222 - 2.5 Shift Instruction

2.1 I/O Instructions2-81. IN#(Input number) / OT#(Output number) / SIN#(Specific input number) /SOUT#(Specific output number) / IG#(Input group numbe

Strona 223

2.1 I/O Instructions2-92. =When an IN# (input number), OT# (output number), SIN# (specific input number), or SOUT# (specific output number) is select

Strona 224

2.1 I/O Instructions2-105. B Variable number / LB Variable number / B [Array number] / LB [Array number] / Byte type constantWhen an IG# (input group

Strona 225

2.1 I/O Instructions2-11(3) WAIT IGH#(2)<>55 (Decimal)=0101 (Binary) Waits until general input signal nos.5 and 7 are turned of

Strona 226

2.1 I/O Instructions2-12PULSEInstruction set:The pulse signal is output to the general output signal only for the specified time. The PULSE instructi

Strona 227 - SFTOF END

2.1 I/O Instructions2-131. OT# (output number) / OG# (output group number) / OGH# (output group number)Choose one of the tags from the following tabl

Strona 228

2.1 I/O Instructions2-143. T=TimeThe following tag can be added or omitted. (1) PULSE OT#(128)The pulse signal is output for 0.30 seconds to general

Strona 229

2.1 I/O Instructions2-15AOUTInstruction set:Outputs the set voltage value to the general-purpose analog output port.1. AO# (Analog output port number

Strona 230

2.1 I/O Instructions2-16ARATIONInstruction set:Starts the analog output corresponding to the speed.ARATION is valid during linear interpolation, circ

Strona 231

2.1 I/O Instructions2-173. V=Basic speedThe following tag can be added or omitted. 4. OFV=Offset voltageThe following tag can be added or omitted. No

Strona 232

iv• Before operating the manipulator, check that servo power is turned OFF when the emergency stop buttons on the front door of the NX100 and progr

Strona 233

2.1 I/O Instructions2-18When the basic voltage is 7.00 V at a motion speed of 150.0 mm/sec for the analog output port number 1, an offset voltage of

Strona 234

2.1 I/O Instructions2-19510147-5-1050 100 150 200Analog voltageMotion speedBasic speedBasic voltageOffset voltage0(V)(mm/sec)

Strona 235

2.1 I/O Instructions2-20ARATIOFInstruction set:Cancels the analog output corresponding to the speed.1. AO# (Analog output port number)Add the followi

Strona 236

2.1 I/O Instructions2-21ANTOUTThe ANTOUT instruction can be used only with parameter S2C508.Instruction set:Carries out the anticipation output funct

Strona 237

2.1 I/O Instructions2-22Anticipation output functionThe anticipation output function is a signal output timing adjustment function to advance or del

Strona 238

2.1 I/O Instructions2-231. AT# (Anticipation output number) / AG# (Anticipation group output num-ber)Choose one of the tags from the following table.

Strona 239

2.1 I/O Instructions2-242. ON/OFFWhen an AT#(anticipation output number) is selected from the table in part 1 of this Explana-tion, add the following

Strona 240

2.1 I/O Instructions2-253. B Variable number / LB Variable number / B [Array number] / LB [Array number] / Byte type constantWhen an AG#(anticipation

Strona 241

2.2 Control Instruction2-262.2 Control InstructionJUMPInstruction set:Jumps to specified label or job. SUBSET STANDARD EXPANDEDAvailable Available Av

Strona 242

2.2 Control Instruction2-271. *Label character string /LABEL:/JOB:/B Variable number /LB Variable number /B [Array number] /LB [Array number] /IG# (I

Strona 243

vDefinition of Terms Used Often in This ManualThe MOTOMAN manipulator is the YASKAWA industrial robot product.The manipulator usually consists of the

Strona 244

2.2 Control Instruction2-282. B Variable number / LB Variable number / B [Array number] / LB [Array number] / IG# (Input group number)When a LABEL: i

Strona 245 - Input No

2.2 Control Instruction2-295. IFThe following tag can be added or omitted.(1) JUMP *1Jumps to *1.(2) JUMP JOB:TEST1 UF#(2) Jumps to the job named TES

Strona 246

2.2 Control Instruction2-30CALLInstruction set:Calls the specified job. SUBSET STANDARD EXPANDEDAvailable Available AvailableFunctionConstructionCALL

Strona 247

2.2 Control Instruction2-311. JOB: / B Variable number / LB Variable number / B [Array number] / LB [Array number] / IG#(Input group number) / QUE/I

Strona 248 - 2.7 Arc Welding Instruction

2.2 Control Instruction2-322. ENTRY=Registration numberWhen a JET#(job registration table number) is selected from the table in part 1 of this Expla-

Strona 249

2.2 Control Instruction2-33TIMERInstruction set:Stops for the specified time.1. T=timerAdd the following tag. (1) TIMER T=12.50Stops for 12.5 second

Strona 250

2.2 Control Instruction2-34* (LABEL)Instruction set:Specifies the label for the jump.1. *Label stringsAdd the following tag.NOP*1JUMP JOB:1 IF IN#(1)

Strona 251 - ARCON is processed again

2.2 Control Instruction2-35’ (COMMENT)Instruction set:Specifies the comment.1. 'Comment stringsAdd the following tag.NOP'Waiting PositionMO

Strona 252 - 2.7 Arc Welding Instruction

2.2 Control Instruction2-36RETInstruction set:Returns from the called job to the original job which has been called.1. IFThe following tag can be add

Strona 253

2.2 Control Instruction2-37NOPInstruction set:Carries out no operation.NOPENDSUBSET STANDARD EXPANDEDNot available Available AvailableFunctionConstru

Strona 254

viDescriptions of the programming pendant keys, buttons, and displays are shown as follows:Description of the Operation ProcedureIn the explanation

Strona 255 - Automatic sticking release

2.2 Control Instruction2-38PAUSEInstruction set:Stops the job temporarily.1. IFThe following tag can be added or omitted.PAUSE IF IN#(12)=ONStops the

Strona 256

2.2 Control Instruction2-39CWAITInstruction set:Waits for the next instruction line to be carried out.CWAIT is used with the NWAIT tag, an additional

Strona 257

2.2 Control Instruction2-40ADVINITInstruction set:When the same variable is used for multiple systems in the optional independent control func-tion,

Strona 258

2.2 Control Instruction2-41ADVSTOPInstruction set:When the same variable is used for multiple systems in the optional independent control func-tion,

Strona 259

2.3 Operating Instruction2-422.3 Operating InstructionCLEARInstruction set:In Data 1, the variable content from the specified number on, is cleared t

Strona 260

2.3 Operating Instruction2-431. B Variable number /LB Variable number /B [Array number] /LB [Array num-ber] /I Variable number /LI Variable number /I

Strona 261 - For arc welding applications

2.3 Operating Instruction2-442. Byte type constant /ALLWhen a B Variable number, LB Variable number, B [Array number], LB [Array number], I Vari-able

Strona 262

2.3 Operating Instruction2-45NOPMOVJ VJ=100.00CALL JOB:2ENDJOB:1 JOB:2NOPMOVJ VJ=100.00CALL JOB:3JUMP JOB:4ENDJOB:3JOB:1 JOB:1JOB:2JOB:4NOPMOVJ VJ=10

Strona 263

2.3 Operating Instruction2-46INCInstruction set:Adds one to the content of the specified variable. SUBSET STANDARD EXPANDEDAvailable Available Availa

Strona 264

2.3 Operating Instruction2-471. B Variable number /LB Variable number /B [Array number] /LB [Array num-ber] /I Variable number/ LI Variable number /I

Strona 265 - Starts weaving operation

vii1 INFORM Manual Outline1.1 About INFORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-11.1.1 With INFORM II . . .

Strona 266 - 1. RB1/RB2/RB3/RB4

2.3 Operating Instruction2-48DECInstruction set:Subtracts 1 from a specified variable.1. B Variable number/LB Variable number/B [Array number]/LB [Ar

Strona 267

2.3 Operating Instruction2-49ExampleNOPSET B000 200*1MOVJ VJ=100.00MOVJ VJ=50.00DEC B000JUMP *1 IF B000=0END1 is repeatedly subtracted from B000 unti

Strona 268

2.3 Operating Instruction2-50SETInstruction set:Sets Data 2 to Data 1.SET <Data 1> <Data 2>SUBSET STANDARD EXPANDEDAvailable Avail

Strona 269 - Reversed

2.3 Operating Instruction2-51B/LB/B[]/LB[]Variable No.I/LI/I[]/LI[]Variable No.D/LD/D[]/LD[]Variable No.R/LR/R[]/LR[]Variable No.Byte typeconstantInt

Strona 270 - Welding”

2.3 Operating Instruction2-521. B Variable number /LB Variable number /B [Array number] /LB [Array num-ber] /I Variable number /LI Variable number /I

Strona 271 - Ends weaving operation

2.3 Operating Instruction2-536BP Variable num-ber/LBP Variable number/BP [Array num-ber]/LBP [Array num-ber]Specifies the number of the base axis p

Strona 272

2.3 Operating Instruction2-542. Byte type constant /B Variable number /LB Variable number /B [Array number] /LB [Array number] /I Variable number /LI

Strona 273 - Construction

2.3 Operating Instruction2-553. Integer type constant /B Variable number /LB Variable number /B [Array number] /LB [Array number] /I Variable number

Strona 274

2.3 Operating Instruction2-564. Double precision type constant /B Variable number /LB Variable number /B [Array number] /LB [Array number] /I Variabl

Strona 275

2.3 Operating Instruction2-575. Real type constant /B Variable number /LB Variable number /B [Array number] /LB [Array number] /I Variable number /LI

Strona 276

viiiMUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-79DIV . . . . . . . . . . . . . . . . . . . .

Strona 277

2.3 Operating Instruction2-586. P Variable number /LP Variable number /P [Array number] /LP [Array num-ber]When a P Variable number, LP Variable numb

Strona 278

2.3 Operating Instruction2-59(1) SET B000 00 is set in B000. (2) SET P000 P001The content of P001 is set in P000. Example

Strona 279

2.3 Operating Instruction2-60ADDInstruction set:Adds Data 1 and Data 2, and stores the result in Data 1.Add <Data 1> <Data 2>SUBSET S

Strona 280

2.3 Operating Instruction2-61B/LB/B[]/LB[]Variable No.I/LI/I[]/LI[]Variable No.D/LD/D[]/LD[]Variable No.R/LR/R[]/LR[]Variable No.Byte typeconstantInt

Strona 281 - 2.8 Handling Instruction

2.3 Operating Instruction2-621. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/I Variable number/LI Variable number/I [Arra

Strona 282

2.3 Operating Instruction2-632. Byte type constant/B Variable number/LB Variable number/B [Array num-ber]/LB [Array number]/I Variable number/LI Vari

Strona 283 - Time (s)

2.3 Operating Instruction2-643. Integer type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable number/LI Va

Strona 284

2.3 Operating Instruction2-654. Double-precision type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable num

Strona 285 - 2.9 Spot Welding Instruction

2.3 Operating Instruction2-665. Real-number type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable number/L

Strona 286

2.3 Operating Instruction2-676. P Variable number/LP Variable number/P [Array number]/LP [Array num-ber]When a P Variable number, LP Variable number,

Strona 287

1.1 About INFORM1-11 INFORM Manual Outline1.1 About INFORM 1.1.1 With INFORM IIThe robot programming language used with NX100 is called INFORM II. I

Strona 288 - 2. MODE=Gun 1 operation mode

2.3 Operating Instruction2-68(1) ADD B000 10Adds 10 to B000, and stores the result in B000.(2) ADD I000 I001Adds I001 to I000, and stores the result

Strona 289

2.3 Operating Instruction2-69SUBInstruction set:Subtracts Data 2 from Data 1, and stores the result in Data 1.SUB <Data 1> <Data 2>SU

Strona 290

2.3 Operating Instruction2-70B/LB/B[]/LB[]Variable No.I/LI/I[]/LI[]Variable No.D/LD/D[]/LD[]Variable No.R/LR/R[]/LR[]Variable No.Byte typeconstantInt

Strona 291 - ( ) LONG

2.3 Operating Instruction2-711. B Variable number/LB Variable number/B [Array number]/LB [Array num-ber]/I Variable number/LI Variable number/I [Arra

Strona 292

2.3 Operating Instruction2-726BP Variable num-ber/LBP Variable number/BP [Array num-ber]/LBP [Array num-ber]Specifies the number of the base axis pos

Strona 293 - STRWAIT GUN#(1) LONG

2.3 Operating Instruction2-732. Byte type constant/B Variable number/LB Variable number/B [Array num-ber]/LB [Array number]/I Variable number/LI Vari

Strona 294

2.3 Operating Instruction2-743. Integer type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable number/LI Va

Strona 295

2.3 Operating Instruction2-754. Double-precision type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable num

Strona 296

2.3 Operating Instruction2-765. Real-number type constant/B Variable number/LB Variable number/B [Array number]/LB [Array number]/I Variable number/L

Strona 297

2.3 Operating Instruction2-776. P Variable number/LP Variable number/P [Array number]/LP [Array num-ber]When a P Variable number, LP Variable number,

Komentarze do niniejszej Instrukcji

Slawomir.wawrzaszek 22 Jan 2024 | 17:21:35