YASKAWA FSP Series Przewodnik Instalacji Strona 37

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 58
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 36
FSP Amplifier Short Form Installation Guide Wiring
In conformance with local electrical codes, ground the FSP Amplifier grounding
terminal (grounding resistance: 100 Ω or less).
Be sure to connect the grounding wire of the servomotor to of the FSP
Amplifier.
Never share the grounding cable or main grounding point with welding
equipment, power equipment or other high-voltage devices. Separate the
grounding cable from wiring of high-voltage equipment.
Make the grounding wire as short as possible.
If two or more FSP Amplifiers are used, ground them as shown in (a) below.
Avoid methods (b) and (c).