FSP Amplifier Short Form Installation Guide Wiring
5.6. AC Power Source Supply
Use the FSP Amplifier AC power source supply according to p roduct ratings.
See the following table for details.
Power
FS P
Amplifier
Motor
Output
Specifications
Connection
Terminals
FSP-A3A* to
FSP-04A*
30, 50, 100,
200, and
400W
1-phase 200VAC to 230VAC
(+10% to -15%), 50/60 Hz
L1, L2 (Main)
LIC, L2C
(Control)
1-phase 220VAC to 230VAC
*1
(+10% to -15%), 50/60 Hz
38
L1, L3 (Main)
Single-
Phase
200V
FSP-08A* and
FSP-15A*
750 W and
1.5kW
1-phase 200VAC to 230VAC
(+10% to -15%), 50/60 Hz
L1C, L2C
(Control)
3-phase 220VAC to 230VAC
(+10% to -15%), 50/60 Hz
L1, L2, L3
(Main)
T hree-
Phase
200V
FSP-10A* to
FSP-30A*
1.0, 2.0, and
3.0kW
1-phase 200VAC to 230VAC
(+10% to -15%), 50/60 Hz
L1C, L2C
(Control)
3-phase 380VAC to 480VAC
(+10% to -15%), 50/60 Hz
L1, L2, L3
(Main)
T hree-
Phase
400V
FSP-05D* to
FSP-50D*
0.5, 1.0, 1.5,
2.0, 3.0 and
5.0kW
DC power supply +24V (±15%)
(not provided by YET)
24 V, 0 V
(Control)
*1. When a power supply of 187V (-15% of 220V) or less is used, alarm A.41, indicating voltage shortage,
may occur when accelerating to max speed with max torque of servomotor.
5.7. DC Power Source Supply
3-Phase 400V FSP Amplifier models require 24VDC for its control circuit. The
user must provide a 24VDC ± 15% power supply with a current capacity of at
least 1 Amp. This power supply must also be able to withstand a surge of up to
3A for 50ms. It should be connected to the terminals marked 24V and 0V on the
FSP Amplifier.
WARNING
• Do not connect AC voltage to these terminals.
Doing so may cause permanent damage to the amplifier.
5.8. Noise Control
• If the signal line is affected by noise, malfunction may result.
• Separate power cables from control cables.
• Make the signal line as short as possible and use twisted-pair wires.
• Never use a line filter (for power input) for servomotor circuit. If
peripheral devices malfunction due to the noise from the FSP Amplifier,
insert a line filter (for output, type LF-310KA, made by Tokin Corp.)
between the servomotor and the FSP Amplifier.
Komentarze do niniejszej Instrukcji