Yaskawa Modbus TCP/IP SI-EM3D Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Yaskawa Modbus TCP/IP SI-EM3D. Yaskawa Modbus TCP/IP SI-EM3D User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Modbus TCP/IP

MANUAL NO. TOEP YAICOM 18AModbus TCP/IPYASKAWA AC Drive 1000-Series OptionInstallation ManualType: SI-EM3D To properly use the product, read this ma

Strona 2

4 Option ComponentsuSI-EM3D Dual-Port Modbus TCP/IP OptionMAIHGEBDFCJKLUndersideA – Ground terminal andinstallation hole <1>B –Port 2 LED (10/10

Strona 3 - Table of Contents

uCommunication Connector CN1The communication connector on the option is a modular RJ45 female connector designatedCN1.CN1 is the connection point for

Strona 4 - 1 Preface and Safety

uOption LED DisplayThe option has four LEDs.Bi-color Status LEDs:• Module status (MS) red/green• Network status (NS) red/greenEthernet LEDs:• Network

Strona 5

NameDisplayOperating Status RemarksColor Status10/100 <1>Green OFF 10 Mbps is established–Green ON 100 Mbps is establishedLINK/ACT<1>Green

Strona 6 - Electrical Shock Hazard

5 Installation ProcedureuSection Safety DANGERElectrical Shock HazardDo not connect or disconnect wiring while the power is on.Failure to comply will

Strona 7

WARNINGFire HazardTighten all terminal screws to the specified tightening torque.Loose electrical connections could result in death or serious injury

Strona 8 - 2 Product Overview

uPrior to Installing the OptionPrior to installing the option, wire the drive, make necessary connections to the drive terminals,and verify that the d

Strona 9 - 3 Receiving

uInstalling the OptionRemove the front covers of the drive before installing the option. Refer to the drive QuickStart Guide for directions on removin

Strona 10 - 4 Option Components

ACNS MSFigure 4 Apply the LED Label3.Make sure the screws on the left and right sides of the option terminal block (J) aretightened with a tightening

Strona 11 - 1 2 3 4 5 6 7 8

4.Connect the ground wire (I) to the ground terminal (K) using one of the remainingprovided screws (H). Connect the other end of the ground wire (I) t

Strona 12 - Option LED Display

Copyright © 2014 YASKAWA ELECTRIC CORPORATION. All rights reserved.All rights reserved. No part of this publication may be reproduced, stored in a re

Strona 13

ABA – Route wires through theopenings provided on theleft side of the frontcover. <1>B – Use the open spaceprovided inside the driveto route op

Strona 14 - 5 Installation Procedure

YaskawaDrive YaskawaDrive YaskawaDrive YaskawaDrive YaskawaDrive YaskawaDrive YaskawaDrive YaskawaDrive YaskawaDrive Star TopologyDaisy-Chained Topolo

Strona 15 - Fire Hazard

DriveMU/T1V/T2W/T3R/L1S/L2T/L3SI-EM3DModbus TCP/IP OptionFE<1>MotorPowerModbus TCP/IP CableModbus TCP/IP CableFigure 9 Option Connection Diagram

Strona 16

DABNS MSTX RXFigure 10 Replace the Front Covers and Digital OperatorNote: Take proper precautions when wiring the option so that the front

Strona 17 - Installing the Option

6 Related Drive ParametersThe following parameters are used to set up the drive for operation with the option. Parametersetting instructions can be fo

Strona 18

No.(Addr.Hex)Name Description ValuesF6-08(036A)<6>Reset CommunicationParameters0: Communication-related parameters (F6-oo/F7-oo)are not reset wh

Strona 19

No.(Addr.Hex)Name Description ValuesF7-14(03F2)Duplex Mode SelectionSelects duplex mode setting.0: Half duplex forced <9>1: Auto-negotiate dupl

Strona 20

<5> The setting specifies that the Torque Reference or Torque Limit is to be provided via network communications(F6-06 = 1). The motor may rotat

Strona 21

7 Modbus TCP/IP MessaginguModbus TCP/IP OverviewThe Modbus TCP/IP protocol is essentially the Modbus protocol over an Modbus TCP/IPnetwork. A master c

Strona 22

Table 7 Drive RegistersAddress(hex)DriveRegister(hex)Description Bit Description2000 4BStatus Word(U1-12)0 During Run1 During Zero Speed2 During Rever

Strona 23 - TX RX

Table of Contents1 PREFACE AND SAFETY...42 PRODUCT OVERVIEW...83 RECEIVING...

Strona 24 - 6 Related Drive Parameters

Address(hex)DriveRegister(hex)Description Bit Description2009 C0 Error Signal 10 Reserved1 Undervoltage (Uv1)2 Control Power Supply Undervoltage (Uv2)

Strona 25

Address(hex)DriveRegister(hex)Description Bit Description200A C1 Error Signal 20 External Fault at input terminal S3 (EF3)1 External Fault at input te

Strona 26

Address(hex)DriveRegister(hex)Description Bit Description200B C2 Error Signal 30 MEMOBUS/Modbus Communication Error (CE)1 Option Communication Error (

Strona 27

Table 8 Enter Command TypesRegister No. Description0900HWrites data into the EEPROM (non-volatile memory) of the drive and enables the data in RAM att

Strona 28 - 7 Modbus TCP/IP Messaging

8 Web InterfaceThe option contains a series of web pages that allow for viewing of status and diagnosticinformation through a standard web browser.The

Strona 29

uHTML Home PageThe main HTML home page provides basic drive and option data and a link to an enhancedweb page. The RSTP enabled home page provides Rap

Strona 30

nRSTP Enabled HTML Home PageFigure 12 RSTP Enabled HTML Home Page8 Web Interface36YASKAWA TOEP YAICOM 18A 1000-Series Option Dual-Port Modbus TCP/IP S

Strona 31

uMain TabThe Main tab shows basic option information such as IP address, MAC address, and firmwareversion.Figure 13 Main Tab View8 Web InterfaceYASKAW

Strona 32 - Enter Command Types

uDrive Status TabThe Drive Status tab shows basic I/O information and drive state information.Figure 14 Drive Status Tab View8 Web Interface38YASKAWA

Strona 33 - H5-11 and the Enter Command

uCustom TabThe Custom tab displays a selection of quick setting parameters.Figure 15 Custom Tab View8 Web InterfaceYASKAWA TOEP YAICOM 18A 1000-Series

Strona 34 - 8 Web Interface

1 Preface and SafetyYaskawa manufactures products used as components in a wide variety of industrial systemsand equipment. The selection and applicati

Strona 35 - HTML Home Page

9 Rapid Spanning Tree ProtocolRapid Spanning Tree Protocol (RSTP) is a mechanism that allows an Ethernet network to beconfigured as a ring or other to

Strona 36 - RSTP Enabled HTML Home Page

10 TroubleshootinguDrive-Side Error CodesDrive-side error codes appear on the drive digital operator. Causes of the errors and correctiveactions are l

Strona 37 - Main Tab

Digital Operator Display Fault NameEF0Option Card External FaultThe alarm function for an external device has been triggered.Cause Possible SolutionsA

Strona 38 - Drive Status Tab

Digital Operator Display Fault NameoFb00Option Card Fault at Option Port CN5-BOption compatibility errorCause Possible SolutionThe option card install

Strona 39 - Custom Tab

nMinor Faults and AlarmsDigital Operator Display Minor Fault NameCALLSerial Communication Transmission ErrorCommunication has not yet been established

Strona 40

uOption Error CodesnOption Fault Monitors U6-98 and U6-99The option can declare error/warning conditions via drive monitor parameters on the drivedigi

Strona 41 - 10 Troubleshooting

uOption CompatibilityA limited number of options may be simultaneously connected to the drive depending on thetype of option.Table 10 below lists the

Strona 42

11 SpecificationsTable 11 Option SpecificationsItem SpecificationModel SI-EM3DSupported Messages• Read Multiple Registers (03H)• Write Single Register

Strona 43

11 SpecificationsThis Page Intentionally Blank48YASKAWA TOEP YAICOM 18A 1000-Series Option Dual-Port Modbus TCP/IP SI-EM3D Installation Manual

Strona 44 - Minor Faults and Alarms

This Page Intentionally BlankYASKAWA TOEP YAICOM 18A 1000-Series Option Dual-Port Modbus TCP/IP SI-EM3D Installation Manual49

Strona 45 - Option Error Codes

uTermsNote: Indicates supplemental information that is not related to safety messages.Drive: Yaskawa 1000-Series AC DriveOption: Yaskawa AC Drive 1000

Strona 46 - Option Compatibility

Revision HistoryThe revision dates and the numbers of the revised manuals appear on the bottom of the back cover.MANUAL NO.Example: TOEP YAICOM 18APub

Strona 48 - This Page Intentionally Blank

YASKAWA AMERICA, INC.2121 Norman Drive South, Waukegan, IL 60085, U.S.A.Phone: (800) YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310http://

Strona 49

NOTICEIndicates a property damage message.NOTICE: may also be indicated by a bold key word embedded in the text followed by an italicized safetymessag

Strona 50 - Revision History

NOTICEObserve proper electrostatic discharge procedures (ESD) when handling the drive andcircuit boards.Failure to comply may result in ESD damage to

Strona 51

2 Product OverviewuAbout this ProductThis option provides a communications connection between the drive and a Modbus TCP/IPnetwork. The option connect

Strona 52 - Installation Manual

3 ReceivingPlease perform the following tasks upon receipt of the option:• Inspect the option for damage. Contact the shipper immediately if the optio

Komentarze do niniejszej Instrukcji