7.8 PHASE LEAD/LAG Instruction (LLAG)
7-22
[Format]
Symbol : LLAG
Full Name : Phase Lead Lag
Category : DDC
Icon :
[Parameter]
Parameter Name Setting
Input · Any integer type and real number type register
· Any integer type and real number type register with subscript
· Subscript register
· Constant
Parameter · Register address (except for # and C registers)
· Register address with subscript (except for # and C registers)
Output · Any integer type and real number type register (except for # and C
registers)
· Any integer type and real number type register with subscript (except for #
and C registers)
· Subscript register
[Program Example]
Integer type operation
MW00100 to MW00105 are used for the parameter table.
Real number type operation
MF00200 to MF00208 are used for the parameter table.