9.9 Inverter Constant Write Function (ICNS-WR)
9-32
Table 9.14 Configuration of Inverter Constant Write Execution Status (STATUS)
Name Bit No. Remarks
System Reserved Bit 0 to Bit 7
Execution sequence error Bit8 The function will not be executed.
Transmission parameter error Bit9 The function will not be executed.
Designated type error Bit10 The function will not be executed.
Designated No. error Bit11 The function will not be executed.
Error in number (amount) of the
designated data
Bit12 The function will not be executed.
Transmission error Bit13 The function will not be executed.
Inverter response error Bit14 The function will not be executed.
Address input error Bit15 The function will not be executed.
Note : In the case of an inverter response error, the error codes from the inverter are indicated in bit
0 to bit 7.
01H(1) : function code error
02H(2) : reference No. error
03H(3) : write-in count error
21H(33) : write-in data upper/lower limit error
22H(34) : write-in error (during running, during UV)
9.9.1 Configuration of the Write-in Data
bn-01
ASR integration time
PG dividing ratio
・
・
・
・
bn-05
bn-14
Cns-No
Cns-Size
Constant data 10
・
・
・
・
Constant data 2
Constant data 1
User register
ASR proportional gain
・
・
・
・
AO optional output gain
・
・
・
・
Acceleration time 1
Inverter Constants
bn-25
bn-06
Cns-Typ
Dat-Adr