7 Data Field
7.2.1 Substatus Field Specification
7-10
7.2 Substatus Data Field
7.2.1 Substatus Field Specification
The substatus field is used to monitor status of subcommands.
Substatus Field
7.2.2 Extension Status Field Specifications
This field is used to monitor extension status.
The SMON, LTMOD_ON, and LTMOD_OFF subcommands can be used to enable monitoring.
L_CMP_CNT (D0-D7)
This counter indicates how many times the latch sequence has been completed during continuous latch oper-
ation. It remains 0 during a normal latch operation.
L_SEQ_NO (D8-D11)
This number indicates the number of latch sequence being completed during a continuous latch operation. It
remains 0 during a normal latch operation.
Byte
18
D7 D6 D5 D4 D3 D2 D1 D0
Reserved Reserved Reserved Reserved Reserved
SBCM-
DRDY
SBWARNG SBALM
Bit Name Description Value Status
D0 SBALM Subcommand alarm occurs.
0 No alarm
1 Alarm occurs
D1 SBWARNG Subcommand warning occurs.
0 No warning
1 Warning
D2 SBCMDRDY
Subcommand Ready
(Subcommand can be received)
0Busy
1Ready
Byte
28
D7 D6 D5 D4 D3 D2 D1 D0
L_CMP_CNT
Byte
29
D15 D14 D13 D12 D11 D10 D9 D8
−−−− L_SEQ_NO
Przeglądanie stron 128