Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands Instrukcja Użytkownika Strona 75

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 142
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 74
4 Motion Commands for Operation
4.2.4 Interpolation Feeding (INTERPOLATE: 34H)
4-10
(2) Related Parameters
Either torque (force) feed forward (TFF) or torque (force) limit (TLIM) can be selected by setting the follow-
ing parameters.
Parameter
No.
Set Value Meaning
Pn81F n.1
Enables the torque (force) feed forward (TFF).
Pn002 n.2
Pn81F n.1
Enables forward/reverse torque (force) limit using TLIM.
Pn002 n.1
Pn81F n.1
When P_CL of OPTION field is set to 1: Uses TLIM as positive torque (force) limit.
When N_CL of OPTION field is set to 1: Uses TLIM as negative torque (force) limit.
Pn002 n.3