3 Commands for Preparation Process
3.2.9 Turn Encoder Power Supply ON (SENS_ON: 23H)
3-18
(3) Monitor Information Field Specifications: MONITOR 1/2/3/4
The monitor information (MONITOR 1/2/3/4) field is used to monitor information selected by the monitor
codes in the monitor selection field.
Applicable Commands:
SV_ON, SV_OFF, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL, SMON, SENS_ON, SENS_OFF, BRK_ON, BRK_OFF, LTMOD_ON, LTMOD_OFF
The MONITOR 1/2/3/4 monitor codes are listed below.
Monitor
Code
Name Description Unit
0POS
Reference position in reference coordinate system
(position after reference filtering)
Reference unit
1 MPOS Reference position Reference unit
2 PERR Position error Reference unit
3 APOS Feedback position in machine coordinate system Reference unit
4LPOS
Feedback latch position in machine coordinate
system
Reference unit
5IPOS
Reference position in reference coordinate system
(position before reference filtering)
Reference unit
6 TPOS Target position in reference coordinate system Reference unit
7–
8 FSPD Feedback speed
Position/torque (force) control: reference
units/s
Speed control: Maximum speed/
40000000H
9 CSPD Reference speed
Position control: Reference units/s
Speed control: Maximum speed/
40000000H
A TSPD Target speed
Position control: Reference units/s
Speed control: Maximum speed/
40000000H
BTRQ
Torque (force) reference (The rated torque is
100%.)
Position/speed control: % (The rated
torque is 100%.)
Torque (force) control: Maximum torque
(force)/40000000H
C–
D–
E OMN1 Option monitor 1 selected in Pn824
F OMN2 Option monitor 2 selected in Pn825
Przeglądanie stron 48