3.2 How to Execute Self-configuration
3-4
3.2 How to Execute Self-configuration
There are two ways to execute self-configuration.
Turning ON the Power After Setting the DIP switch “CNFG”
Set the DIP switch “CNFG” on the Machine Controller to ON, and then turn ON the power to execute self-configura-
tion. The setting of the DIP switch “INIT” causes some differences in the results of self-configuration.
After execution of self-configuration, be sure to execute Save to Flash to save the results of self-configuration in the
Machine Controller.
For MP2100, MP2100M, MP2500, MP2500M, MP2500D, and MP2500MD Machine Controllers, the DIP switch is
not commonly used for self-configuration. Use an MPE720 as described below to execute self-configuration.
Using an MPE720
Start the Engineering Manager of MPE720 and open the Module Configuration Window. Select Order - Self Config-
ure All Modules from the main menu of the Module Configuration Window, or select a module for which self-config-
uration is to be executed in the Module Configuration Window and then select Module Self-configuration.
Refer to 3.4.1 ( 1 ) How to Open the Module Configuration Window for information on how to open the Module Con-
figuration Window.
The results of configuration will be as follows.
CNFG INIT Result
ON ON
Module Configuration Definition will be updated.
All the detected axes (slave devices) will be allocated to the MECHATROLINK Transmission
Definition.
Some of the SERVOPACK parameters will be written in the SVB Definition.
ON OFF
Module Configuration Definition will be updated.
The axes that have already been allocated to the MECHATROLINK Transmission Definition
will stay unchanged. Only the axes that are newly detected by self-configuration will be newly
allocated.
The column showing the deleted axis will appear blank in the MECHATROLINK Transmission
Definition Window.
The SVB definitions of the axes that have already been allocated to the MECHATROLINK
Transmission Definition Window will not be updated.
INIT Result
Self Configure All Mod-
ules
(Self-configuration for all
modules)
Module Configuration Definitions will be updated.
The axes that have already been allocated to the MECHATROLINK Transmission Definition will
remain unchanged. Only the axes that are newly detected by self-configuration will be newly allo-
cated.
The column showing the deleted axis will appear blank in the MECHATROLINK Transmission
Definition Window.
The SVB definitions of the axes that have already been allocated to the MECHATROLINK Trans-
mission Definition Window will not be updated.
Module Self-configura-
tion
(Self-configuration for in-
dividual module)
The slave devices (slave axes) of the selected module will be detected.
The axes that have already been allocated to the MECHATROLINK Transmission Definition will
stay unchanged. Only the axes that are newly detected by self-configuration will be newly allo-
cated.
The column showing the deleted axis will appear blank in the MECHATROLINK Transmission
Definition Window.
The SVB definitions of the axes that have already been allocated to the MECHATROLINK Trans-
mission Definition Window will not be updated.