Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Modul Instrukcja Użytkownika Strona 82

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 140
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 81
4.3 Motion Parameter Lists
4.3.1 Fixed Parameter List
4-6
4.3 Motion Parameter Lists
4.3.1 Fixed Parameter List
The following table provides a list of SVB and SVR motion fixed parameters.
Refer to the section numbers indicated in the Reference column for details of each fixed parameter.
For information on SVR, refer to 1.3 SVR Virtual Motion Module.
No. Name Contents SVB SVR Reference
0
Selection of Operation Modes
0: Normal Operation Mode
Yes Yes
4.4.1 ( 1 )
1: Axis unused
Yes Yes
2: Simulation mode
Yes
3: Servo Driver Transmission Reference Mode
Yes
4 and 5: Reserved for system use.
−−
1
Function Selection Flag 1
Bit 0: Axis Selection (0: Finite length axis/1: Infinite length axis)
Set to 0 for linear type.
Yes Yes
4.4.1 ( 2 )
Bit 1: Soft Limit (Positive Direction) Enable/Disable
(0: Disabled/1: Enabled)
Yes
Bit 2: Soft Limit (Negative Direction) Enable/Disable
(0: Disabled/1: Enabled)
Yes
Bit 3: Overtravel Positive Direction Enable/Disable
(0: Disabled/1: Enabled)
Yes
Bit 4: Overtravel Negative Direction Enable/Disable
(0: Disabled/1: Enabled)
Yes
Bits 5 to 7: Reserved for system use.
−−
Bit 8: Interpolation Segment Distribution Processing
Yes
Bit 9: Simple ABS Rotary Pos. Mode (Simple absolute infinite axis
position control) (0: Disabled/1: Enabled)
Set to 0 for linear type.
Yes
Bit A: User Constants Self-writing Function
Yes
Bits B to F: Reserved for system use.
−−
2
Function Selection Flag 2
Bit 0: Communication Abnormality Detection Mask
Yes
4.4.1 ( 3 )
Bit 1: WDT Abnormality Detection Mask
Yes
Bits 2 to F: Reserved for system use.
−−
3
Reserved for system use.
−−
4
Reference Unit Selection
0: pulse 3: inch
1: mm 4: μm
2: deg
For linear type, 0 (pulse), 1 (mm), and 4 (μm) can be
used. If 2 (deg.) or 3 (inch) is selected, the selected unit
will be converted to mm.
Yes Yes
4.4.1 ( 4 )
5
Number of Digits below Deci-
mal Point
1 = 1 digit
Yes Yes
6
Travel Distance per Machine
Rotation
(rotary motor)
1 = 1 user unit
Yes Yes
Linear Scale Pitch
(linear motor)
1 = 1 user unit
Yes Yes
8
Se
rvo Mo
tor Gear Ratio
1 = 1 rev
Invalid for linear type
Yes Yes
9
Machine Gear Ratio
1 = 1 rev
Invalid for linear type
Yes Yes
10
Infinite Length Axis Reset Po-
sition (POSMAX)
1 = 1 user unit
Invalid for linear type
Yes Yes 4.4.1 ( 5 )
12
Positive Software Limit Value
1 = 1 user unit
Yes
4.4.1 ( 6 )
14
Negative Software Limit Value
1 = 1 user unit
Yes
16
Backlash Compensation
Amount
1 = 1 user unit
Yes 4.4.1 ( 7 )