Yaskawa MotionSuite Series Machine Controller Programming Instrukcja Użytkownika Strona 97

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 187
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 96
MotionSuite™ Series Machine Controller Programming Manual Chapter 3: Advanced Programming Methods
3-12
Note: Even within the functions, the SA, MA, IA, OA, DA, #A, CA can still be used.
S System Register
SB, SW, SL,
SFnnnnn
(SAnnnnn)
Same as the DWG registers.
Because these registers are the same as the
DWG registers, use caution when referencing
the same function from a DWG that has a
different priority level.
Same as
the DWG
registers.
M Data Register
MB, MW,
ML,
MFnnnnn
(MAnnnnn)
I Input Register
IB, IW, IL,
IFhhhh
(IAhhhh)
O Output Register
OB, OW,
OL,
Ofhhhh
(OAhhhh)
C Constant Register
CB, CW,
CL,
CFhhhhh
(CAnnnnn)
Function Register (Continued)
Przeglądanie stron 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 186 187

Komentarze do niniejszej Instrukcji

Brak uwag